Products  Fans  By Mounting Type  Flameproof Miniduct – FPMD404
Download Catalogue  Autocad  Print Friendly Version

Flameproof Miniduct – FPMD404

Flameproof Miniduct

Performance Curve - FPMD404

Description

The Compact Series of Flameproof Miniduct fans has been specifically designed for duct mounting and to ventilate hazardous or explosive environments.
There are 4 sizes in the range extending from 250 to 400mm diameter.
Features
  • Galvanised steel casing with red powder-coated finish.
  • Anti-static blades.
  • Suitable for ducted installations.
  • Can be mounted at any angle.
  • Designed for single-phase supply.
  • Motors comply with Ex d, Group II, Zone 1, T6 protection - see Special Note.
  • IP66 rated.
  • Construction
    Galvanised steel casing with red powder-coated finish.
    Axial impellers have glass reinforced anti-static blades.
    Motors
    Type - squirrel cage induction motor.
    Electricity Supply - 230V, single-phase, 50Hz.
    Bearings - sealed-for-life, ball
    Maximum ambient temperature 40 °C.
    These motors are not speed-controllable.
    Internal Thermal Protection
    The motor is fitted with thermal protection to conform to the requirements of AS1359. IECEx certification and classification of T6 does not take into account abnormal operation such as locked rotor where the temperature of the surfaces may exceed 85°C. If this is an issue with your application, further protection should be fitted.
    Testing
    Air flow tests to ISO5801:1997, 'Type 'D' Installation (ducted inlet and outlet).
    Noise tests to BS848:Part 2, 1985.
    Special Note
    These products have a Certificate of Conformity issued under the IEC Ex Certification Scheme for Explosion Protected Electrical Equipment.
    This certificate, number IEC Ex TSA 14.0024X, covers these fans for Ex d GroupII, Zone 1 protection. These fans are approved for gas Groups llA, llB and llC, have temperature classification T6 and enclosure protection IP66.

    Suggested Specification

    The fans shall be of the Compact Flameproof Miniduct Series, as designed and manufactured by Fantech Pty Ltd and shall be of the model numbers shown on the schedule/drawings.

    They shall be approved for gas Groups llA, llB and llC, have temperature classification T6 and enclosure protection IP66.

    They shall have a galvanised steel casing with a red powder-coated finish and be fitted with glass reinforced anti-static blades.

    All data shall be based on tests to ISO5801:1997, Type 'D' Installation for air flow and to BS848:Part 2, 1985 for noise.

    Technical Data - FPMD404

    Speed [rps]Avg. dBA @ 3mkWatts (Input)Amps Max.°C Approx. Weight [kg]
    23520.1214018

    Sound Data

    Type631252505001K 2K4K8K
    Inlet7272 686669 676350

    Dimensions

    ABCDE
    470438400410250

    *All dimensions in mm, unless otherwise stated

    Wiring Diagram


    Diagram shown is for single-speed only.
    For 2-speed and special motors, contact Fantech for details.

    Ancillaries