Products  Fans  By Application  Gamma Ultra - Vertical – GUD356V
Autocad  Print Friendly Version

Gamma Ultra - Vertical – GUD356V

Gamma Ultra - Vertical

Performance Curve - GUD356V

Description

The Gamma Ultra Series of Mixed-Flow roof units has been designed for use in commercial ducted exhaust applications. These compact and low profile units are fitted with birdmesh to prevent the entry of birds and vermin into the ducting or building. They are available in 9 sizes, extending from 250 to 630mm diameter.
Features
  • Robust, lightweight construction.
  • Choice of speeds available.
  • Compact, low profile design.
  • Designed for down flow or vertical exhaust applications.
  • Shutters are an optional extra for single fan units. The pressure loss across the shutter has to be added to the system pressure before making selections.
  • Can be mounted at angle up to 30°.
  • Most 3-phase motors are 2-speed star/delta design.
Construction
Cowls are UV-stabilised plastic.
Impellers are Mixed-Flow design and made from high performance injection moulded composite material.
Steel components have a corrosion resistant finish.
Bird-mesh guards are fitted as standard to both downflow and vertical exhaust models.
Motors
Type - external rotor, squirrel cage induction motor
Electricity supply - 230V, single and 415V, three-phase, 50Hz
Bearings - sealed-for-life, ball
Speed-controllable using electronic or auto-transformer controllers
Most three-phase units are fitted with 2-speed star/delta design motors
Internal Thermal Protection
Thermal protection is supplied as standard on all motors
Testing
Air flow tests based on ISO5801
Noise tests based on ISO13347-3

Suggested Specification

The Gamma Ultra Series roof ventilators shall be of the vertical exhaust type as designed and manufactured by Fantech Pty. Ltd.
Impellers shall be made from high performance injection moulded composite material. They shall be Mixed-Flow design and driven by speed-controllable external rotor motors with integral thermal overload protection.
The windband shall be of the vertical exhaust design and formed from plastic. Steel components shall be corrosion protected.
All performance data shall be for a complete assembled unit to ISO5801 for air flow and ISO13347-3 for noise.

Technical Data - GUD356V

Speed [rps]Avg. dBA @ 3mkWatts (Input)Amps Max.°C Approx. Weight [kg]
15400.130.366013

Sound Data

Type631252505001K 2K4K8K
Inlet6664 655655 534532
Outlet6766 666260 564735

Dimensions

ABCDEFG
40050075640670410417

*All dimensions in mm, unless otherwise stated

Wiring Diagram


Diagram shown is for single-speed only.
For 2-speed and special motors, contact Fantech for details.

Ancillaries