Ezifit Thru Roof Exhaust Fan - Bushfire Code Compliant (BAL-29) – ECE152-BFC-29
Location Designation
Project Notes
Ezifit Thru Roof Exhaust Fan - Bushfire Code Compliant (BAL-29)
Description
The Ezifit Roof Series, with BAL-29 bushfire code compliance, has been developed and tested for exhaust air applications in bushfire prone regions. They are driven by a high performance centrifugal fan and have a low profile design. They can exhaust from a number of points within the building and are available in 150 and 200mm fan sizes.
Features
  • Robust, galvanised steel construction.
  • Speed-controllable with electronic controller.
  • High performance, low noise backward-curved centrifugal impellers.
  • High quality bronze mesh provides ember protection.
  • Comes with convenient 3-pin plug and lead.
  • Designed for downflow discharge.
  • Can be mounted at angles up to 30°.
  • Powder coated finish is an optional extra.
  • Compliant to AS3959:2009 up to and including BAL-29.
  • Robust, galvanised steel construction.
  • Speed-controllable with electronic controller.
  • High performance, low noise backward-curved centrifugal impellers.
  • High quality bronze mesh provides ember protection.
  • Comes with convenient 3-pin plug and lead.
  • Designed for downflow discharge.
  • Can be mounted at angles up to 30°.
  • Powder coated finish is an optional extra.
  • Compliant to AS3959:2009 up to and including BAL-29.
  • Construction
    Cowls are of galvanised steel
    Ember protection - bronze mesh with max. 2mm aperture
    Backward-curved centrifugal impellers
    3-pin plug and lead included
    Motor
    Type - external rotor, squirrel cage induction motors
    Electricity supply - 230V, single-phase, 50/60Hz
    Bearings - sealed-for-life, ball
    Can be speed controlled
    Testing
    Air flow to ISO5801:2007
    Based on noise tests to BS848:Part 2, 1985

    Technical Data - ECE152-BFC-29

    Speed [rps]Avg. dBA @ 3mkWatts (Input)Amps Max.°C Approx. Weight [kg]
    41440.070.3754

    Sound Data

    Type631252505001K 2K4K8K
    Inlet6160 655960 575146

     

    Ezifit Thru Roof Exhaust Fan - Bushfire Code Compliant (BAL-29) – ECE152-BFC-29
    Suggested Specification
    The roof ventilators shall be of the Ezifit Roof Series with bushfire code compliance as designed and manufactured by Fantech Pty Ltd.
    The backward-curved centrifugal fans shall be direct-driven by continuous rated, speed-controllable external rotor motors with thermal protection.
    They shall be constructed from galvanised steel, be of downflow discharge design and include a 3-pin plug and lead.
    Ember protection mesh shall be bronze or steel with openings a maximum of 2mm.
    All data shall be based on tests on a complete assembled unit according to ISO5801:2007 for air flow and BS848:Part 2, 1985 for noise.
     

    Dimensions

    ABCD
    140100700285

    *All dimensions in mm, unless otherwise stated

    Contacts



    OFFICES & AGENTS

    Victoria
    Fantech Pty. Ltd.
    Tel:+61 (03) 9554-7845

    New South Wales
    Fantech Pty. Ltd.
    Tel:+61 (02) 8811-0400

    Uniair Distributors Pty. Ltd.
    Tel:+61 (02) 4961-6088
    Refrigeration and Air Supplies
    Tel:+61 (02) 4226-5133

    South Australia
    Fantech Pty. Ltd.
    Tel:+61 (08) 8294-0530

    Queensland
    Fantech Pty. Ltd.
    Tel:+61 (07) 3299-9888
    Capricorn Air Conditioning
    Tel:+61 (07) 4775-5222

    Northern Territory
    Fantech Pty. Ltd.
    Tel:+61 (08 ) 8947-0447

    Western Australia
    Systemaire Pty. Ltd.
    Tel:+61 (08) 9209-4999

    Tasmania
    Major Air Pty. Ltd.
    Tel:+61 (03) 62736455

    ACT
    Idealair Group Pty. Ltd.
    Tel:+61 (02) 6280-5511

    Auckland
    Fantech (NZ) Ltd.
    Tel:+64 (09) 444-6266

    Christchurch
    Fantech (NZ) Ltd.
    Tel:+64 (03) 379-8622

    Wellington
    Fantech (NZ) Ltd.
    Tel:+64 (04) 566-0532