Heritage Series - Centrifugal Fans for Hazardous Locations – CHD504Ex
Location Designation
Project Notes
Heritage Series - Centrifugal Fans for Hazardous Locations
Description
The Heritage Series of roof units has been designed to permit easy access for cleaning. They can handle clean air, grease laden air or toxic gases.

Construction
Cowls are of galvanised steel with a powder-coated finish.
Stainless steel construction is an optional extra.

Motors
Type - standard squirrel cage motors
Electricity supply - single or three-phase to suit a wide range of voltages and frequencies.
Bearings - sealed-for-life, ball.
Speed-controllable using inverters.
Explosion-proof motors for three-phase supply can be fitted to all selections.

Internal Thermal Protection
Thermistors can be supplied on request.

Testing
Air flow data based on tests to BS848:Part 1, 1980.
Noise data based on tests to BS848:Part 2, 1985.

Special Features
The motor is mounted out of the airstream.
This design is suitable for a wide range of applications, extending from the handling of toxic or explosive gases to elevated temperature applications. Appropriate motors are fitted for each application.
The windband is held in place with toggle clamps to permit easy access for cleaning and maintenance.
Can be mounted at angles up to 15°.

Technical Data - CHD504Ex

Speed [rps]Avg. dBA @ 3mkWatts (Input)Amps Max.°C Approx. Weight [kg]
24601.12.64057

Sound Data

Type631252505001K2K4K8K
Inlet8787827673737370

 

Heritage Series - Centrifugal Fans for Hazardous Locations – CHD504Ex
Suggested Specification
The Heritage Series of centrifugal roof ventilators shall be as designed and manufactured by Fantech Pty. Ltd.

Impellers shall be backward-curved centrifugal design and driven by standard motors.

The cowl shall be of pressed galvanised steel and powder-coated after manufacture.

The windband shall incorporate quick-release catches to provide easy access for cleaning and maintenance.

All data shall be based on fans fully tested to BS848:Part 1, 1980 for air flow and BS848:Part 2, 1985 for noise, in fully certified laboratories.

 

Dimensions

ABCDEF
62072060900540820

*All dimensions in mm, unless otherwise stated

Contacts



OFFICES & AGENTS

Victoria
Fantech Pty. Ltd.
Tel:+61 (03) 9554-7845

New South Wales
Fantech Pty. Ltd.
Tel:+61 (02) 8811-0400

Uniair Distributors Pty. Ltd.
Tel:+61 (02) 4961-6088
Refrigeration and Air Supplies
Tel:+61 (02) 4226-5133

South Australia
Fantech Pty. Ltd.
Tel:+61 (08) 8294-0530

Queensland
Fantech Pty. Ltd.
Tel:+61 (07) 3299-9888
Capricorn Air Conditioning
Tel:+61 (07) 4775-5222

Northern Territory
Fantech Pty. Ltd.
Tel:+61 (08 ) 8947-0447

Western Australia
Systemaire Pty. Ltd.
Tel:+61 (08) 9209-4999

Tasmania
Major Air Pty. Ltd.
Tel:+61 (03) 62736455

ACT
Idealair Group Pty. Ltd.
Tel:+61 (02) 6280-5511

Auckland
Fantech (NZ) Ltd.
Tel:+64 (09) 444-6266

Christchurch
Fantech (NZ) Ltd.
Tel:+64 (03) 379-8622

Wellington
Fantech (NZ) Ltd.
Tel:+64 (04) 566-0532