Hunter Titan HVLS Fan Kits
Description
There are large industrial HVLS fans, and there’s the Titan. Available in five sizes from 4.2m to 7.3m this master of the air thoroughly mixes the air within an indoor space eliminating uneven temperatures. It can reduce energy costs, improve comfort and increase productivity. The Titan features an efficient direct drive permanent magnet motor designed to be quieter, generate large amounts of torque and is up to 25% more efficient than gear driven HVLS fans. These Hunter HVLS fans not only provide widespread air movement, they also have a sleek and contemporary design that will complement any commercial space.
Features
  • Blades are formed with a unique twist profile for each individual fan size to maximise air flow and minimise noise levels
  • Simplifies installation with pre-installed bolts, quick connect blades, pre-wired drop tube, pre-aligned mounting brackets and I-beam clamp
  • Effective coverage area ranges from 484m2 (4.2m Titan HVLS) to 1,369m2 (7.3m Titan HVLS)
  • Highly efficient 5 blade configuration designed to maximise airflow performance
  • Manage up to 5 fans with Hunter’s Basic Controller or a network of 10 fans with the Premium Hunter Controller
  • Can be connected to a Building Management System (BMS)
  • 15-year Non-Prorated Warranty (Conditions apply)

Selecting the Correct HVLS Fan

Not all HVLS fans are the same. Whether you are moving air through a commercial space, temperature sensitive facility or large industrial warehouse, choosing the right size Hunter fans with the most effective spacing will give the best return on your customer’s investment. To assist with choosing the most effective HVLS fans, our web-based step by step application makes selection easy. Once on the HVLS page, simply enter the width, length, and height of the area, together with the ambient temperature and desired cooling effect from the fans. The selection tool will provide a number of possible options that list the number of fans, fan sizes and suggested spacing is maximised across its entire length.

The Fantech HVLS selection tool performs calculations to ASHRAE 55-2017 “Thermal Environmental Conditions for Human Occupancy”. This determines the cooling effect of Hunter Titan HVLS fans at different locations relative to the fans (under normal conditions). It can also estimate energy savings when using HVLS fans in air-conditioned spaces, or when HVLS fans are used for de-stratification.

  • Blades are formed with a unique twist profile for each individual fan size to maximise air flow and minimise noise levels
  • Simplifies installation with pre-installed bolts, quick connect blades, pre-wired drop tube, pre-aligned mounting brackets and I-beam clamp
  • Effective coverage area ranges from 484m2 (4.2m Titan HVLS) to 1,369m2 (7.3m Titan HVLS)
  • Highly efficient 5 blade configuration designed to maximise airflow performance
  • Manage up to 5 fans with Hunter’s Basic Controller or a network of 10 fans with the Premium Hunter Controller
  • Can be connected to a Building Management System (BMS)
  • 15-year Non-Prorated Warranty (Conditions apply)

Selecting the Correct HVLS Fan

Not all HVLS fans are the same. Whether you are moving air through a commercial space, temperature sensitive facility or large industrial warehouse, choosing the right size Hunter fans with the most effective spacing will give the best return on your customer’s investment. To assist with choosing the most effective HVLS fans, our web-based step by step application makes selection easy. Once on the HVLS page, simply enter the width, length, and height of the area, together with the ambient temperature and desired cooling effect from the fans. The selection tool will provide a number of possible options that list the number of fans, fan sizes and suggested spacing is maximised across its entire length.

The Fantech HVLS selection tool performs calculations to ASHRAE 55-2017 “Thermal Environmental Conditions for Human Occupancy”. This determines the cooling effect of Hunter Titan HVLS fans at different locations relative to the fans (under normal conditions). It can also estimate energy savings when using HVLS fans in air-conditioned spaces, or when HVLS fans are used for de-stratification.

Construction
Aircraft grade aluminium blades that are formed with a unique twist profile for each individual fan.
Motor
  • HVLS fans from Hunter use 3-phase direct drive, permanent magnet motors that come with several advantages:
  • Generates large amounts of torque while operating at slow speeds
  • Whisper quiet gearless operation at less than 55dBA @ 3metres
  • Offers significant savings on running costs and efficient performance under partial loads
  • Up to 25% more energy efficient than gearbox or gear driven fan motor
  • Extremely durable with fewer components
  • Comes with a pre-configured VSD with simple push and turn plugs to connect to motor and touch screen
Testing

Technical Data - HUNTER2-TITAN24

Speed [rps]Avg. dBA @ 3mkWatts (Input)Amps Max.°C Approx. Weight [kg]
193

 

Hunter Titan HVLS Fan Kits – HUNTER2-TITAN24
Suggested Specification
 
Contacts



OFFICES & AGENTS

Victoria
Fantech Pty. Ltd.
Tel:+61 (03) 9554-7845

New South Wales
Fantech Pty. Ltd.
Tel:+61 (02) 8811-0400

Uniair Distributors Pty. Ltd.
Tel:+61 (02) 4961-6088
Refrigeration and Air Supplies
Tel:+61 (02) 4226-5133

South Australia
Fantech Pty. Ltd.
Tel:+61 (08) 8294-0530

Queensland
Fantech Pty. Ltd.
Tel:+61 (07) 3299-9888
Capricorn Air Conditioning
Tel:+61 (07) 4775-5222

Northern Territory
Fantech Pty. Ltd.
Tel:+61 (08 ) 8947-0447

Western Australia
Systemaire Pty. Ltd.
Tel:+61 (08) 9209-4999

Tasmania
Major Air Pty. Ltd.
Tel:+61 (03) 62736455

ACT
Idealair Group Pty. Ltd.
Tel:+61 (02) 6280-5511

Auckland
Fantech (NZ) Ltd.
Tel:+64 (09) 444-6266

Christchurch
Fantech (NZ) Ltd.
Tel:+64 (03) 379-8622

Wellington
Fantech (NZ) Ltd.
Tel:+64 (04) 566-0532