Table of Contents Table of Contents
Previous Page  169 / 416 Next Page
Information
Show Menu
Previous Page 169 / 416 Next Page
Page Background

© FANTECH

2016

D

ROOF MOUNTED FANS

D-23

Model

CD...D/V

CE...D/V

Nom.

Speed

r/s

Low Air

Flow

High Air

Flow kW Amps* kW Amps* 63 125 250 500 1k 2k 4k 8k

192.

42

Inlet 45

47

0.07 0.30 -

-

21 22 22 19 12 11 9 2

224.

23

Inlet 38

39

0.05 0.26 -

-

29 27 22 19 11 11 9 3

252.

42

Inlet 56

58

0.19 0.83 -

-

27 22 20 19 12 11 10 2

254.

23

Inlet 41

42

0.08 0.37 -

-

30 28 22 19 11 11 9 3

284.

23

Inlet 44

45

0.09 0.40 -

-

31 28 22 19 11 11 9 3

314.

23

Inlet 47

48

0.15 0.66

0.18 0.37

35 29 21 18 10 10 8 2

316.

15

Inlet 40

42

0.07 0.54 0.09 0.15

34 26 22 18 12 12 6 0

354.

23

Inlet 52

51

0.28 1.25

0.19 0.51

28 26 22 19 10 12 11 1

356.

15

Inlet 43

43

0.07 0.32 0.13 0.22

33 25 22 19 14 8 3 0

404.

23

Inlet 56

54

0.49 2.20

0.45 1.40

28 26 21 18 11 12 12 5

406.

15

Inlet 44

44

0.17 0.80

0.23 0.73

33 28 22 19 14 10 7 3

408.

11

Inlet 39

40

-

-

0.16 0.30

33 26 19 16 14 14 12 3

454.

23

Inlet 59

57

0.76 3.50

0.77 1.47

27 25 20 17 11 12 12 8

456.

15

Inlet 47

46

0.43 2.00

0.44 0.90

31 30 21 18 13 11 9 5

458.

11

Inlet 41

43

-

-

0.15 0.35

33 26 19 16 14 14 12 3

504.

23

Inlet 62

61

1.30 5.70

1.39 2.70

26 26 21 15 12 12 12 9

506.

15

Inlet 50

50

0.53 2.50

0.65 1.20

30 29 22 16 12 10 8 6

508.

11

Inlet 43

45

0.23 1.15 0.30 0.50

32 26 20 16 14 13 12 4

564.

23

Inlet 65

65

-

-

2.16 4.10

26 27 23 14 13 12 12 10

566.

15

Inlet 54

54

0.84 4.10

0.69 1.45

29 29 23 15 12 10 8 7

568.

11

Inlet 44

47

0.32 1.50 0.39 0.79

30 27 22 15 15 11 11 6

634.

23

Inlet 69

70

-

-

4.30 7.35

24 28 24 12 13 11 12 10

636.

15

Inlet 60

58

-

-

1.10 2.20

28 29 24 14 12 10 8 8

638.

11

Inlet 46

50

-

-

0.68 1.20

28 27 23 14 14 9 10 6

716.

15

Inlet 63

61

-

-

2.20 4.30

28 29 24 14 12 10 8 8

718.

11

Inlet 48

53

-

-

0.66 2.00

28 27 23 14 14 9 10 6

711.

9

Inlet 41

46

-

-

0.28 1.20

28 27 23 14 14 9 10 6

Electrical data in

bold

type refers to fans fitted with 2-speed star/delta motors as standard.

* Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order.

** Add the In-Duct Spectrum Corrections to the closest dB(A) level shown on the fan curve to obtain the In-Duct Sound Power Levels on the Inlet Side of the unit.

† The CE316. model is not speed-controllable.

Model No.

CD…

CE… A

†

B

†

C DØ E

†

F G

Approx.

weight

kg.

Approx.

volume

m

3

192-254

260 310 50 430 370 200 244 4

0.05

284-316

310 410 75 500 575 330 334 8

0.13

354-408

400 500 75 640 670 410 417 18

0.22

454-568

620 720 75 908 890 530 540 38

0.52

634-711

710 810 75 1260 1180 650 695 69

1.28

Model No.

TCD…

TCE… H J K L M N P Q

Approx.

weight

kg.

Approx.

volume

m

3

252-254

600 260 650 310 770 430 50 244 8

0.10

314-316

700 310 800 410 892 500 75 334 16

0.18

354-408

900 400 1000 500 1196 640 75 417 36

0.37

1330 620

720 1630 908 75 540 76

0.92

454-568

1430

Twin Fan Units

Single Fan Units

CE..1 ph.

Avg dB(A) @ 3m

CD..3 ph.

In-duct Spectrum Corrections, dB**

Dimensions, mm

Dimensions, mm

TECHNICAL DATA

DIMENSIONS

GAMMA SERIES