FLEXLINE
®
SERIES - DIRECT DRIVE
E
© FANTECH
2016
E-5
CENTRIFUGAL FANS; SWSI & DWDI
Model
Nom.
speed,
rev/sec
Avg. dB(A) @ 3m
FLD..DD
Low Air
High Air
Flow
Flow
kW Amps* 63 125 250 500 1k 2k 4k 8k
312
48
Inlet
60
61
1.50 3.22
31 30 21 19 7 13 13 2
Outlet
62
63
27 26 19 20 11 15 12 2
314
23
Inlet
48
49
0.55 1.38
34 28 20 17 9 9 7 1
Outlet
50
51
30 24 18 18 13 11 6 -1
316
15
Inlet
41
43
0.37 1.10
33 25 21 17 11 11 5 -1
Outlet
46
43
30 26 17 17 15 10 6 2
352
48
Inlet
66
65
2.20 4.30
23 26 21 19 6 14 15 2
Outlet
63
66
20 28 16 8 13 17 13 2
354
23
Inlet
53
52
0.55 1.38
27 25 21 18 9 11 10 0
Outlet
55
54
23 26 15 16 15 13 7 0
356
15
Inlet
44
44
0.37 1.10
32 24 21 18 13 7 2 -1
Outlet
48
46
30 26 17 17 15 10 6 2
404
23
Inlet
57
55
0.55 1.38
27 25 20 17 10 11 11 4
Outlet
59
57
25 25 16 16 15 12 9 5
406
15
Inlet
45
45
0.37 1.10
32 27 21 18 13 9 6 2
Outlet
50
49
26 23 16 16 14 11 8 0
454
23
Inlet
60
58
0.75 1.80
26 24 19 16 10 11 11 7
Outlet
62
60
27 23 16 16 15 11 10 9
456
15
Inlet
48
47
0.37 1.10
30 29 20 17 12 10 8 4
Outlet
51
51
23 21 16 15 14 12 10 -1
504
23
Inlet
63
62
1.1 2.6
25 25 20 14 11 11 11 8
Outlet
66
65
25 23 16 15 15 9 8 7
506
15
Inlet
51
51
0.55 1.70
29 28 21 15 11 9 7 5
Outlet
53
53
26 24 17 16 15 12 10 1
564
23
Inlet
66
66
3.00 6.30
25 26 22 13 12 11 11 9
Outlet
70
70
24 24 16 15 16 7 7 6
566
15
Inlet
55
55
1.10 2.90
28 28 22 14 11 9 7 6
Outlet
56
56
29 26 18 16 15 11 9 2
568
11
Inlet
45
48
0.55 1.51
29 26 21 14 14 10 10 5
Outlet
51
52
32 23 17 16 15 12 9 0
634
23
Inlet
70
71
4.00 8.03
23 27 23 11 12 10 11 9
Outlet
76
75
23 26 17 15 17 6 6 6
636
15
Inlet
61
59
1.1 2.8
27 28 23 13 11 10 7 7
Outlet
62
59
31 27 18 16 14 10 7 3
638
11
Inlet
47
51
0.55 1.51
27 26 22 13 13 8 9 5
Outlet
52
54
33 23 17 16 15 10 8 -1
716
15
Inlet
64
62
2.20 5.14
27 28 23 13 11 9 7 7
Outlet
65
62
31 27 18 16 14 10 7 3
718
11
Inlet
49
54
1.10 3.02
27 26 22 13 13 8 9 5
Outlet
55
57
33 23 17 16 15 10 8 -1
In-Duct Spectrum Corrections, dB**
FLD..DD
* Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order.
** Add the In-Duct Spectrum Corrections from the table to the closest dB(A) level shown on the fan curve to obtain the In-Duct Sound Power Level. Note: there are noise
levels for both the Inlet and Outlet Sides of the units.
TECHNICAL DATA & NOISE DATA
3ph