Motor

Frame

Motor

Shaft

Dia.

App.

wt.

kg** kW# FLA LRC Eff%

kW# FLA LRC Eff%

kW# FLA LRC Eff%

kW# FLA LRC Eff%

D71

B

14 11

0.37 0.9 6.1 67.7 0.37 1.0 4.1 69.3 -

-

-

-

-

-

-

-

D71

14 16

0.55 1.3 6.1 76.0 -

-

-

-

-

-

-

-

-

-

-

-

D80

A

19 18

0.75 1.5 7.0 83.4 0.55 1.4 4.8 72.8 0.37 1.1 2.8 66.5 -

-

-

-

D80

B

19 22

1.1 2.2 7.3 84.4 0.75 1.9 7.5 82.2 0.55 1.7 3.1 68.2 -

-

-

-

D90S

24 25

1.5 2.9 8.4 86.4 1.1 2.6 6.2 84.0 0.75 2.0 5.5 77.7 -

-

-

-

D90L

24 30

2.2 4.3 8.7 86.5 1.5 3.4 7.0 86.2 1.1 2.8 6.2 79.9 0.55 2.0 3.26 65.5

D100L

28 38

3.0 5.7 9.0 86.7 2.2 4.7 8.3 86.5 1.5 3.6 6.0 81.9 0.75 2.1 5.7 77.2

D100L

28 44

-

-

-

-

3.0 6.2 8.0 87.4 -

-

-

-

1.1 2.9 5.6 78.6

D112M

28 52

4.0 7.1 9.2 89.6 4.0 8.2 7.3 88.9 2.2 5.2 5.7 84.9 1.5 4.2 4.7 80.8

D132S

38 70

5.5 9.9 8.0 90.2 5.5 10.6 7.1 90.2 3.0 6.6 5.9 86.3 2.2 5.1 5.6 84.9

D132S

38 73

7.5 13.3 7.9 90.6 -

-

-

-

-

-

-

-

-

-

-

-

D132M

38 85

-

-

-

-

7.5 14.3 7.4 90.5 4.0 8.8 6.4 87.2 3.0 7.0 5.8 85.6

D132M

38 87

-

-

-

-

-

-

-

-

5.5 11.8 6.6 87.9 -

-

-

-

D160M

42 130

11.0 19.5 8.0 92.0 11 20.7 7.4 91.0 7.5 15.4 6.4 89.2 4.0 9.4 5.7 86.0

D160M

42 130

15.0 26.4 7.8 92.4 -

-

-

-

-

-

-

-

5.5 12.8 6.0 86.6

D160L

42 150

18.5 32.5 7.6 92.2 15 27.6 7.5 91.8 11 22.7 6.9 89.9 7.5 16.4 6.3 87.6

D180M

48 185

22 38.6 7.9 93.0 18.5 32.8 7.9 92.3 -

-

-

-

-

-

-

-

D180L

48 200

-

-

-

-

22 38 7.9 92.8 15 29.8 6.5 90.8 11 24.5 5.8 88.7

D200L

55 260

30 53 9.0 94.1 30 53 8.8 93.6 18.5 35 8.4 92.3 15 32.8 6.6 90.8

D200L

55 265

37 65 6.5 93.3 -

-

-

-

22 42.5 8.8 92.5 -

-

-

-

D225S

55/60 310

-

-

-

-

37 64 7.6 94.1 -

-

-

-

18.5 38.5 5.6 91.4

D225M

55/60 330

45 79 9.0 93.7 45 79 9.0 94.3 30 54 7.4 92.6 22 44 5.2 92.0

D250M

60/65 430

55 93 8.9 94.6 55 95 9.1 94.4 37 65 8.0 93.2 30 59 6.0 92.4

D280S

65/70 660

75 126 9.2 94.9 75 126 7.4 95.2 45 78 7.8 93.5 37 73 6.8 93.0

D280M

65/80 700

90 147 7.1 95.4 90 151 6.6 95.9 55 96 9.0 94.2 45 86 6.7 93.4

D315S

80 1000 110 181 6.2 95.5 110 185 7.2 95.8 75 131 7.0 94.4 55 101 7.1 93.7

D315M

80/85 1100 132 222 6.0 95.5 132 221 7.0 95.5 90 155 7.1 95.0 75 139 7.3 94.5

D315L

80/85 1180 160 263 5.4 95.5 160 261 7.2 95.7 110 189 7.0 95.4 90 168 6.5 94.8

D315L

80/85 1320 -

-

-

-

-

-

-

-

132 229 7.8 95.6 110 205 6.5 95.3

© FANTECH

2016

REFERENCE INFORMATION

ELECTRICAL DATA & WEIGHTS

O-11

O

* The figures in this table are to be used as a guide only.

# For direct drive axial flow fan applications in normal ambient

temperatures, airstream cooling enables the power available

from the motors to be increased without detriment to the

motor. Fantech will utilise this facility whenever possible.

** Motor weight will vary depending on the manufacturer. Our

data is based upon a commonly used brand of motor.

Efficiency is at 100% of full load and will vary depending on

the manufacturer. Our data is based upon a commonly used

brand of motor.

Starting Amps

Direct-on-line (D.O.L.).

= Full Load Amps

×

Locked Rotor

Current Multiplier

= FLA

×

LRC

Where:

DOL = Direct-on-line

FLA = Full Load Amps

LRC = Locked Rotor Current Multiplier

The data on this page does not apply to external rotor motors.

FLA

×

LRC

3

Star/delta starting =

2 Pole*

48 rev/sec

4 Pole*

24 rev/sec

6 Pole*

16 rev/sec

8 Pole*

12 rev/sec

STANDARD THREE-PHASE MOTORS