NEW GENERATION SERIES

ROOF MOUNTED FANS

D

© FANTECH

2016

D-16

RDE - downflow exhaust

RDS - downflow supply

RVE - vertical exhaust

RSS - smoke-spill

Fan diameter in cm

Fan speed, no. of poles

A =150

B = 250

C = 350

Aluminium blades,

A

GRP,

P

Nylon,

N

No. of blades

Blade pitch angle, deg.

Hub diameter code

D= 400

F = 550

G = 255

-

The heavy duty New Generation Series of axial roof units has

been designed for a wide range of free intake and ducted

applications. These exhaust fans are suitable for a wide range of

commercial and industrial applications for handling clean air

through to smoke-spill.

There are 9 sizes in the series extending from 315 to 1250mm

diameter.

Typical Applications

Can exhaust from a range of commercial and industrial

applications such as warehouses and factories with air

qualities ranging from clean air to toxic, noxious and corrosive

gases and smoke-spill.

Features

O

Robust, heavy duty construction.

O

New Generation downflow supply air units can also be

supplied.

O

Adjustable pitch impellers provide performances to suit a

wide range of applications.

O

Impellers can be GRP, aluminium, nylon or anti-static to suit

the application, GRP is standard.

O

Shutters are a standard component for the RVE

and RSS models and are an optional extra for the RDE

units (see

Special Notes

).

O

Can be mounted at angles up to 30

o

.

O

All standard motors are speed-controllable using variable

speed drives.

O

Can be used for free intake and ducted applications.

O

Wide choice of speeds available.

O

Multi-speed motors, as well as motors to meet Ex d, Ex e,

Ex nA and Ex tD Standards can be supplied.

O

For installations prone to high prevailing winds refer to

Special Notes.

Construction

Galvanised steel bases; cowls/wind bands are of plastic,

fibreglass or galvanised steel.

The RVE and RSS models are all steel construction.

Impeller blades can be GRP, aluminium, nylon or anti-static to

suit the application. GRP is standard.

Motors

Type - squirrel cage induction motors

Electricity supply - motors to suit a wide range of voltages and

frequencies can be supplied

Bearing - sealed-for life, ball

Speed-controllable using variable speed drives

See pages

O-3/4

for details on these motors

Motors with 2-speed windings, or to meet Ex d, Ex e, Ex nA and

Ex tD Standards, can be supplied

When fans are required for non-standard air applications this

must be nominated at the time of enquiry

Internal Thermal Protection

Thermistors can be provided on all motors except when

Standards specifically exclude their use.

Testing

Air flow tests to BS848:Part 1, 1980

Noise tests to BS848:Part2, 1985

Discharge damper fail-open latching

An additional requirement of AS/NZS1668.1:1998 with respect to

un-sprinklered buildings (300

o

C for 30mins) requires dampers to

fail-open during smoke spill operation.

The fail-open discharge damper latches come in two forms;

the first being a manual release type requiring manual closing

after the fan has been run. The second design, an electro-mechanical

type permits the shutter latch to release and close automatically

after the fan stops.

For advice on smoke-spill wiring requirements refer to

AS/NZS1668.1:1998.

See page

C-8

for details of the smoke-spill range.

Wiring Diagram

See pages

N-6/7

, diagrams

DD 1, 2, 3, 9

.

Special notes

The quick select envelope performance curves shown on pages

D-18/19

give a guide to fan size, noise level and speed.

Accurate selections, including comprehensive noise data, can

be obtained from your local Fantech office or from the Fans by

Fantech Product Selection Program. Refer to Fantech for

performances at speeds other than shown.

When shutters are fitted ensure the roof unit is mounted with the

shutter spindle pointing down the roof. When shutters are fitted

to the RDE models derate the performance by 15-20%. Where

prevailing winds are high we recommend the fitting of

Magloks®, see page

J-8

for details. For capacities greater than

shown for the New Generation Series refer to the HC and SS

series on pages

D-60/62

The New Generation RSS Series of smoke-spill fans has been

fully tested to meet the air performance and high temperature

requirements of Standards AS/NZS1668.1:1998 and

AS4429:1999.

DESCRIPTION

SMOKE-SPILL APPLICATIONS

HOW TO ORDER