HERITAGE SERIES

ROOF MOUNTED FANS

D

© FANTECH

2016

D-48

The Heritage Series of vertical exhaust centrifugal roof

ventilators shall be as designed and manufactured by Fantech

Pty Ltd.

The cowl shall be of powder coated galvanised steel unless

specified otherwise. Impellers shall be backward-curved

centrifugal design and driven by standard TEFC motors unless

specified otherwise.

The windband shall incorporate quick-release toggle clamps to

provide easy access for cleaning and maintenance.

All models shall be fully tested as a complete assembled unit to

ISO5801: 2007 for air flow and to ISO3744: 2010 for noise.

Variable speed drives

Ref.

M-8/13

CBD - Backdraft shutter

Ref. J-2

Model

CHD..

CHE..

63 125 250 500 1k 2k 4k 8k

314

Inlet

35 29 21 18 10 10 8 2

316

Inlet

34 26 22 18 12 12 6 0

354

Inlet

28 26 22 19 10 12 11 1

356

Inlet

33 25 22 19 14 8 3 0

404

Inlet

28 26 21 18 11 12 12 5

406

Inlet

33 28 22 19 14 10 7 3

454

Inlet

27 25 20 17 11 12 12 8

456

Inlet

31 30 21 18 13 11 9 5

504

Inlet

26 26 21 15 12 12 12 9

506

Inlet

30 29 22 16 12 10 8 6

564

Inlet

26 27 23 14 13 12 12 10

566

Inlet

29 29 23 15 12 10 8 7

568

Inlet

30 27 22 15 15 11 11 6

634

Inlet

24 28 24 12 13 11 12 10

636

Inlet

28 29 24 14 12 10 8 8

638

Inlet

28 27 23 14 14 9 10 6

716

Inlet

28 29 24 14 12 10 8 8

718

Inlet

28 27 23 14 14 9 10 6

In-Duct Spectrum Corrections, dB*

* Add the In-Duct Spectrum Corrections to the closest dB(A) level shown on the

fan curve to obtain the In-Duct Sound Power Level on the Inlet Side of the unit.

VZ Run-on timer

Ref. M-14

DESCRIPTION

ANCILLARY EQUIPMENT

NOISE DATA

SUGGESTED SPECIFICATION

HOW TO ORDER

The Heritage Series of vertical exhaust roof units has been

designed for use in ducted exhaust applications. It features

a high performance centrifugal fan and removable windband

which makes cleaning and maintenance easy.

There are 8 sizes in the series extending from 315 to 710mm

diameter.

Typical Applications

Can exhaust air at normal to high temperatures for applications

such as commercial kitchens and bakeries. Can also

exhaust toxic or explosive gases in industrial applications.

Features

O

Durable galvanised steel construction with powder

coated finish.

O

Designed to handle clean air, grease laden air, toxic

noxious and explosive gases as well as handling air at

elevated temperatures.

O

Motor is mounted out of the airstream.

O

Motors to suit hazardous conditions can be fitted to some

models.

O

Special finishes, such as epoxy coating can be supplied.

O

Available in a range of speeds to suit specific

applications.

O

Windband can be easily removed to allow easy access

for cleaning and maintenance.

O

Can be mounted at angles up to 15°.

Construction

Cowls are of galvanised steel with a powder-coated finish.

Impellers are a backward-curved centrifugal design.

Windband is fitted with quick-release toggle clamps to

facilitate cleaning and maintenance.

Stainless steel construction is an optional extra.

Motors

Type - standard TEFC squirrel cage induction motors.

Electricity supply - single or three-phase to suit a wide range

of voltages and frequencies.

Bearings - sealed-for-life, ball.

Speed-controllable using variable speed drives.

Multi-speed motors can be supplied.

Motors to meet Ex e, Ex nA and Ex tD

Standards can be fitted to some models.

See pages

O-3

/

7

for details on these motors.

Internal thermal Protection

Thermistors can be fitted on request

Testing

Air flow to ISO 5801: 2007

Noise tests to ISO3744: 2010

Wiring Diagram

See pages N-6/7 diagrams