Table of Contents Table of Contents
Previous Page  253 / 416 Next Page
Information
Show Menu
Previous Page 253 / 416 Next Page
Page Background

G

© FANTECH

2016

G-7

COOLING AND DE-STRATIFICATION FANS

BLADETEC - COOLING AND DE-STRATIFICATION FANS

B

Screen

(Frame) Insert

Drop-tube

Frame

C

(In some installations this may

be removed or cut down)

D

(Distance from

top of bracket

to blade tip at full

speed)

(Distance

from top of

bracket

to blade tip

at rest)

BladeTec Commercial Fan

E

B

C

(In some installations this may

be removed or cut down)

Drop-tube

(Distance from

top of bracket

to blade tip at full

speed)

(Distance

from top of

bracket

to blade tip

at rest)

D

BladeTec Industrial Fan

Screen

(Frame) Insert

Frame

E

Model

Number

ØA B C D E

BTC-08

2440 1190 460 1016 1016

BTC-10

3050 1190 460 997 1016

BTC-12

3660 1190 460 978 1016

Dimensions, mm

Model

Number

ØA B C D E

BTI-08

2440 1302 460 1067 1067

BTI-12

3660 1302 460 991 1016

BTI-16

4880 1604 765 1195 1271

BTI-20

6100 2985 2142

2470 2597

BTI-24

7320 2985

2142

2369 2547

Dimensions, mm

Model

Number

Max Fan

Speed

rev/min

Air

Flow

m

3

/sec

Avg

dB(A)*

Power

kW Amps

App

Wt.

kg

BTI-08 152

38

50-62 1.5 3.6 121.8

BTI-12 100

62

50-62 1.5 3.6 125.5

BTI-16 72

97

50-62 1.5 3.6 129.1

BTI-20 58

136 50-62 1.5 3.6 132.7

BTI-24 48

186 50-62 1.5 3.6 136.4

Model

Number

Max. Fan

Speed

rev/min

Air

Flow

m

3

/sec

Avg

dB(A)*

Power

kW Amps

App

Wt.

kg

BTC-08 120

36

40-52 0.75 2.9 63.6

BTC-10 100

43

40-52 0.75 2.9 65.9

BTC-12 80

44

40-52 0.75 2.9 68.2

BladeTec Commercial Fans

VELOCITY PROFILE

BladeTec Commercial Fans

Area of

Influence

Air

Velocity

m/s

Perceived

cooling

degrees

o

C

BTC-08 BTC-10 BTC-12

A

2.0 5 to 7

2.4

3.0

3.7

B

0.9 3 to 4

3.0

4.6

6.0

C

0.5 2 to 3

18.0

24.4

30.4

* Avg. dB(A) depends on fan speed Measured 6100mm below

and 6100mm from the fan’s centre.

* Avg. dB(A) depends on fan speed. Measured 6100mm below

and 6100mm from the fan’s centre

BladeTec Industrial Fans

Area of influence per fan’s sizes

(Diameter in meters)

Area A

Area B

Area C

BTC-12

BTC-10

BTC-08

TECHNICAL DATA

1 phase

3 phase

DIMENSIONS

Area

of

Influence

Air

Velocity

m/s

Perceived

cooling

degrees

o

C

08 12 16 20 24

A

2.8 6 to 8 2.4 3.7 4.9 6.1 9.8

B

1.3 3 to 5 4.5 9.1 12.2 13.0 15.2

C

0.9 3 to 4 6.0 15.0 18.0 30.0 36.0

D

0.5 2 to 3 45.0 48.0 55.4 57.9 58.0

Area of influence per fan’s sizes

(Diameter in meters)

BTI-08

BTI-12

BTI-16

BTI-20

BTI-24

Area A

Area B

Area C

Area D

BladeTec Industrial Fans

BTI-

BladeTec Fan

BladeTec Fan