WALL, WINDOW & CEILING MOUNTED FANS
A
A-6
© FANTECH
2016
The Vogue Series of modern ceiling/wall mounted fans is
suitable for commercial and light industrial applications
where powerful air flow and pressure performance are required.
Typical Applications
Suitable for a broad range of commercial and industrial exhaust
applications, ie. laundries, cellars and bars.
Features
O
Modern square plate, flush to the ceiling design.
O
Choice of speeds available.
O
Sturdy and robust construction.
O
Quick fitting swing locks retain the fan in place in
suspended ceilings or plasterboard walls and ceilings.
O
Holes incorporated for fixing to brick or concrete.
O
Grille can be easily removed for cleaning.
O
Can be used for ducted systems.
O
Can be mounted in any position.
O
Range of matched ancillaries are also available.
O
Models include plug and lead.
O
Reverse air flow can be provided (see Special Note)*.
Construction
The fan plate is of injection-moulded ABS plastic and the
impellers are of galvanised steel with a black powder coated
finish. The grille can be readily removed for cleaning. Access for
wiring is from the rear.
Motors
Type - external rotor, squirrel cage induction motor.
Electricity supply - single-phase 230V, 50Hz
Bearings - sealed-for-life, ball.
Speed-controllable.
Motor protection IP44.
See pages
O-2/3
for details on these motors.
If flameproof motors are required, refer to page
A-26/27
for full
selection information.
Internal Thermal Protection
Thermal contacts fitted as standard on all sizes.
Testing
Air flow tests to ISO5801:2004
Noise tests to BS848:Part 2 1985
*Special Note
Derate the air flow by at least 20% if the air flow direction
is reversed.
Not suitable for mounting above cook tops in kitchen
applications. Refer to Ring Plate Series, see page
A-8.
The fans shall be of the Vogue Series designed and
manufactured by Fantech Pty Ltd.
The axial impellers shall be direct-driven by speed-controllable
external rotor motors with integral thermal protection.
The square plates shall be of ABS plastic and the impellers from
powder coated, galvanised steel.
All models shall be fully tested to ISO5801:2004 for air flow and
BS848:Part 2, 1985 for noise.
VCW - Vogue
Fan diameter in cm
Fan speed, no. of poles
R - reverse flow if required
VCW
DESCRIPTION
SUGGESTED SPECIFICATION
HOW TO ORDER
VOGUE SERIES
Ducting, Louvres & Grilles
Ref.
L-6/14
VCW..DA - Duct
Adapter Ref.
A-7
WT - Wall tube
Ref.
J-11
VA - Speed controller
Ref.
M-5
VZ - Run-on timer
Ref.
M-14
Model
Number
VCW..
63 125 250 500 1k 2k 4k
202
78 69 68 66 69 65 60
204
60 70 54 56 54 49 40
254
63 64 57 57 57 54 47
302
63 66 74 75 80 75 71
304
60 64 64 61 64 62 55
306
53 57 55 53 54 52 44
In-duct Sound Power Levels
L
w
dB re 1pW
TECHNICAL DATA
* Amperages shown are a guide only. Refer to our Sales Department for accurate
figures at time of order.
Model
Number
VCW..
Free
Air
m
3
/s
Fan
Speed
rev/sec
Avg.
dB(A)
@ 3m Watts Amps*
Max.
°C
202
0.22 43
52
70 0.36 50
204
0.13 24
39
30 0.14 60
254
0.28 23
40
60 0.28 60
302
0.66 41
62
180 0.79 50
304
0.48 22
47
90 0.41 50
306
0.36 16
37
50 0.23 50
VCW.. 1 ph.
NOISE DATA
ANCILLARY EQUIPMENT