Table of Contents Table of Contents
Previous Page  34 / 416 Next Page
Information
Show Menu
Previous Page 34 / 416 Next Page
Page Background

WALL, WINDOW & CEILING MOUNTED FANS

A

A-12

© FANTECH

2016

Model

Number

Fan

Dia.

mm

Nom.

Speed

rev/sec

Avg.

dB(A)

@ 3m Exh. Sup.

Watts Amps

App.

wt.

kg.

HV-150..

150 30

39 0.06 n/a 32 0.19 2.0

HV-230..

230 21

43 0.17 0.09 34 0.15 3.5

HV-300..

300 19

46 0.31 0.2 68 0.30 5.1

WALLRODSPK - Wall rods

Ref.

J-10

WP - Wall plate

Ref.

J-11

Weather Cap

Ref.

A-13

SRS - Reversing switch

Ref.

A-13

The Stylvent Series can be wall or window mounted and is

suitable for a wide range of applications. The 230 and 300

models can be wired for exhaust or supply mode or dual purpose

using an optional reversing switch.

Typical Applications

Supply or exhaust air in toilets, shower rooms, conference rooms,

living rooms, restaurants, etc. in both domestic and commercial

installations.

Features

O

Available in 3 sizes for 230V supply.

O

Models 230 and 300 are suitable for supply or exhaust

applications. Model 150 is suitable for exhaust only.

O

For applications requiring both supply and exhaust

a reversing switch is available.

O

Electric shutters prevent outside air entering building when

fan is switched off.

O

IPX4 rated.

O

Tough and long lasting ABS plastic.

O

Maximum ambient of 40°C.

O

Optional weather Cap for protection against harsh external

conditions.

O

For wall mounting, a kit of threaded “wall rods” and sleeves

can be supplied as an optional extra. Caters for walls

ranging in thickness from 25 to 300mm.

Construction

Weather and impact resistant plastic housings.

Motors

Type - the HV-150 is shaded pole and the HV-230 and 300 are

external rotor motor.

Electricity supply - single-phase, 230V, 50Hz.

Bearings - sleeve on the HV-150 and ball on the HV-230 and 300.

Single speed - not suitable for speed control.

Internal Thermal Protection

150 - internal fuse; 230 and 300 - auto-reset type.

Testing

Air flow to ISO5801:1997

Noise to BS848:Part 2, 1985

Wiring Diagram

See page

N-8

, diagram

ER 6, 8

The above graph shows exhaust flow rates only.

The approximate flow rate in supply mode is 50% of high-speed

exhaust rate.

‘AE’ Range* - switch operated

HV.. 1 ph.

Free Air

m

3

/sec

WT - Wall tube

Ref.

J-11

DESCRIPTION

TECHNICAL DATA

ANCILLARY EQUIPMENT

HOW TO ORDER

SUGGESTED SPECIFICATION

VZ - Run-on timer

Ref.

M-14

STYLVENT SERIES

The Stylvent Series of wall/window fans shall be as supplied

by Fantech Pty. Ltd. and be of the model numbers shown.