M-15

© FANTECH

2016

CONTROLLERS, VSD, SENSORS & RUN-ON TIMERS

RUN-ON TIMERS

The VZM0-28TS plug-in run-on timer is

designed to permit the supply of

electricity to motors so they can continue

to operate for a predetermined time.

This unit is designed for multiple switch

inputs to operate a single-phase fan with

a 3-pin plug. The mains supply

connection is wired directly into the

terminals of the run-on timer. No 4 pin

outlet is required.

Run-on time is adjustable from 0-30 min

with a start delay of 0-5 min.

Can be used with VZ-INSE switch.

Warning

Not to be used with fans with EC motors

or inverters.

TYPE - VZM

TECHNICAL DATA

Model Number Run-On Time Start Delay Max. Amps Enclosure Size, mm

VZM0-28TS

0-30 min

0-5 min

5

153W x 110H x 60D

SUGGESTED WIRING ARRANGEMENT

4-PIN PLUG SUPPLY WITH PLUG-IN OUTLET

The VZ6-4PL plug-in run-on timer is

designed to permit the supply of

electricity to motors so they can continue

to operate for a predetermined time.

This unit is designed for single-phase

fans fitted with a 3-pin plug. The VZ6-4PL

has a 900mm lead and 4-pin plug for

connection to a 4-pin outlet.

Run-on time is fixed at 6 minutes.

Warning

Not to be used with fans with EC motors

or inverters.

Model Number Run-On Time Start Delay Max. Amps Enclosure Size, mm

VZ6-4PL

6 min

n/a

5

153W x 110H x 60D

TECHNICAL DATA

TYPE - VZ-PL

SUGGESTED WIRING ARRANGEMENT

M

DIRECT WIRED SUPPLY WITH PLUG-IN OUTLET.

MULTI-SWITCH INPUT