© FANTECH
2016
REFERENCE INFORMATION
O-7
O
MOTOR INFORMATION
FANS FOR Ex d AND Ex e
APPLICATIONS
Fans for Ex d and Ex e applications, or indeed any hazardous application, can be
constructed of special materials and incorporate special features.
Anti-static impellers and earthing leads are just some of the features we can provide.
ELECTRONICALLY COMMUTATED (EC) DC MOTORS
INTRODUCTION
The Electronically Commutated DC motors featured in this catalogue are external-rotor
DC motors which are suitable for AC mains supply. These motors have no wear and
tear elements such as collectors or carbon brushes which used to be an undesirable
component of DC motors and would require regular maintenance. The EC units consist
of a brushless DC external-rotor motor with an EC controller that commutates the
current in the motor windings electronically. The EC controller monitors the motor and
provides interfaces for easy control of the drive. EC motors provide a high level of
motor efficiency and carry on-board features that offers almost limitless flexibility in
terms of automatic and manual fan speed control.
TEMPERATURE RANGE
These motors are generally suitable for operating in ambients from -25ºC to +60ºC.
ENCLOSURE STANDARD
The motor enclosure standard is IP54 in accordance with the appropriate Standards.
ELECTRICAL DETAILS
Motors are suitable for 240V or 415V, 50 or 60Hz supply. These motors should not be
speed controlled by VSD or VA controller.
Insulation; Motor insulation is Class F with a 60ºC winding temperature rise.
BEARINGS
Motors are fitted with sealed-for-life maintenance free bearings.
PARAMETER SETTINGS
Parameters of the EC fans are programmed in our factory for best possible operation to
suit the specific application requirements. It is necessary for the mechanical designer or
contractor to provide details as to the application and system control requirements at
the time of order.
PROTECTION
The EC motors feature their own integral current overload and over-temperature
protection. No other electrical protection is required with these units.