WALL, WINDOW & CEILING MOUNTED FANS
A
A-18
* Amperages shown are a guide only, refer to our Sales Department for accurate figures at time of order.
** Use inverter controllers for variable speed.
Electrical data in
bold
type refers to fans that are fitted with 2-speed star/delta motors as standard. High speed data shown.
Δ
Maximum ambient is 40°C when being speed controlled.
The In-duct Sound Power Levels are for the Outlet Side of the fan; Inlet Side values are generally 1-2 dB lower. The levels are based on the fans operating at approximately
50% of peak pressure.
Model
CP..
Nom.
Speed
rev/sec
Avg.
dB(A)
@ 3m kW Amps* Frame** kW Amps*
Max.
amb
°C 63 125 250 500 1k 2k 4k 8k
0254
23
42
0.09 0.90 -
0.12 0.50
70
Δ
66 64 61 60 56 55 51 45
0314
23
45
0.09 0.90 -
0.12 0.50
70
Δ
69 67 63 63 60 57 53 49
0314HP
23
49
0.09 0.90 -
0.12 0.50
70
Δ
65 69 69 62 65 64 57 44
0354
23
49
0.09 0.90 -
0.12 0.50
70
Δ
71 70 65 67 66 59 55 54
0354HP
23
52
0.09 0.90 -
0.12 0.50
70
Δ
68 72 72 65 68 67 60 47
0404
23
52
0.25 1.80 -
0.37 1.40
70
Δ
71 72 68 70 69 64 61 56
0404HP
23
54
0.25 1.80 -
0.37 1.40
70
Δ
68 70 70 69 71 69 61 52
0406
15
44
0.12 1.05 -
0.18 0.68
70
Δ
67 63 66 63 61 53 48 43
0454
23
54
0.25 1.80 -
0.37 1.40
70
Δ
74 75 72 71 70 67 64 56
0454HP
23
57
0.25 1.80 -
0.37 1.40
70
Δ
71 73 73 72 74 72 64 55
0456
14
46
0.12 1.05 -
0.18 0.68
70
Δ
66 64 66 64 61 58 54 45
0504
23
58
0.55 3.60 -
0.55 1.75
70
Δ
77 81 78 73 72 72 69 62
0504HP
23
62
0.55 3.60 -
0.55 1.75
70
Δ
73 74 74 76 79 76 74 62
0506
14
51
0.18 1.55 -
0.25 0.94
70
Δ
72 67 69 68 69 63 57 51
0564
23
62
0.75 4.90 -
0.75 2.00
70
Δ
81 83 80 79 78 75 73 67
0564HP
23
63
0.75 4.90 -
0.75 2.00
70
Δ
76 74 77 78 80 77 75 66
0566
14
57
0.25 2.20 -
0.25 0.94
70
Δ
76 73 76 76 73 71 60 56
0634
23
66
-
-
-
1.50 4.30
70
Δ
81 82 86 84 80 78 77 72
0636
14
60
0.55 6.00 -
0.55 2.00
70
Δ
83 80 78 77 76 73 68 59
0714/1
23
68
-
-
D100La 2.20 4.60 40
90 80 84 83 83 82 81 76
0714/2
23
71
-
-
D100Lb 3.00 6.20 40
87 84 87 87 86 84 84 75
0714/3
23
73
-
-
D112M 4.00 8.00 40
91 90 93 91 87 86 83 77
0716/1
16
63
-
-
D90S 0.75 2.20 40
85 79 77 83 78 73 71 63
0716/2
16
63
-
-
D90L
1.10 3.00 40
84 81 82 83 78 73 72 61
0716/3
16
69
-
-
D100L 1.50 3.30 40
90 84 85 89 86 79 72 68
0804/1
23
78
-
-
D132S 5.50 10.50 40
90 83 89 92 95 93 88 81
0804/2
23
79
-
-
D132M 7.50 15.80 40
96 93 94 95 94 93 89 82
0806/1
16
67
-
-
D100L 1.50 3.30 40
90 86 85 87 82 77 73 65
0806/2
16
71
-
-
D132S 3.00 6.30 40
92 84 88 89 87 84 78 69
CPE.. 1 ph.
CPD.. 3 ph.
In-duct Sound Power Levels
L w dB re 1pW
TECHNICAL DATA & NOISE LEVELS
© FANTECH
2016
COMPACT 2000 SERIES