Table of Contents Table of Contents
Previous Page  81 / 416 Next Page
Information
Show Menu
Previous Page 81 / 416 Next Page
Page Background

JETSTREAM FAN

®

SERIES

© FANTECH

2016

B

B-21

C D

A

ØE

F

Airflow

B

Model

Number

JCE...

Speed

Setting 125 250 500 1k 2k 4k 8k

152-1

High 59 57 59 64 63 56 46

152-3

High 59 57 59 64 63 56 46

Mid

50 54 52 54 55 46 36

Low 48 46 42 44 46 31 17

202-3

High 66 63 64 66 64 60 55

Mid

54 52 49 51 48 42 35

Low 50 47 43 43 39 31 23

In-duct Sound Power Levels

L w dB re 1pW

Sound Power Levels shown are for the Inlet Side of unit.

DA - 150Ø duct adaptor

(to suit Ø100mm DWV pipe)

CC - Circular attenuator

Ref.

H-16

SJK - Backdraft Damper

Ref.

J-3

Plug-In Run-on Timer

and Speed Controller*

Ref.

M-16

Ducting, Louvres & Grilles

Ref.

L-6/14

Hard Wired Adjustable

Run-on Timer

Ref.

M-14/15

* Speed Controller suitable for JCE152-1 (SJK) only

Model

JCE...

A B

C D EØ F

152

350 163 235 210 147 355

202

375 240 268 241 197 380

Dimensions, mm

† Applicable only when Smooth Flow Damper is fitted

Model

Number

JCE...

Speed

Setting

Fan

Speed

rev/sec

Avg.

dB(A)

@ 3m Watts Amps

Max.

Amb

°C

152-1

High 41

47

70 0.30 50

152-3

High 41

47

65 0.29 50

Mid 32

39

50 0.25 50

Low 21

29

43 0.22 50

202-3

High 42

50

103 0.42 50

Mid 31

34

74 0.31 50

Low 19

26

67 0.19 50

JCE.. 1ph.

RSK - Backdraft Dampers

Ref.

J-3

FC - Fast clamp

Ref.

J-5

Ceiling Grilles

Ref.

L-13/14

DIMENSIONS

TECHNICAL DATA

NOISE DATA

SPECIAL FEATURES

Snap-Fit Mounting Bracket

The Snap-Fit Mounting Bracket

can be installed on-site

beforehand and the fan

simply clips into position at final

fit-out. 3 holes are provided for 1 or 2 point

mounting.

The bracket includes grommets and a spring design which

provides vibration isolation for the fan - no other means of

vibration isolation is necessary.

3-Speed Switch

The integrated 3-speed switch (on JCE152-3

and JCE202-3 models) is ideal for air flow

adjustment when commissioning.

Smooth Flow Backdraft Damper

The SJK, Smooth Flow Backdraft Damper,

is a patented design with outstanding

performance characteristics. These

characteristics result in a 50% higher air flow

for the 152 model and 15% for the 202 model

when compared to using spring loaded

dampers.

q

V

- Volume Flow, m /s

3

p Damper, Pa

0.02

0.04

0.1

0.2 0.3

0.06

0

20

50

10

RSK150

RSK200

SJK200

SJK150

30

40

Comparative Pressure Losses

Smooth Flow vs. Spring Butterfly

SJK

RSK

Scan the QR Code

to view more

information online.

DUCT MOUNTED FANS

ANCILLARY EQUIPMENT