Table of Contents Table of Contents
Previous Page  155 / 416 Next Page
Information
Show Menu
Previous Page 155 / 416 Next Page
Page Background

© FANTECH

2016

D

ROOF MOUNTED FANS

BETA INDUSTRIAL SERIES

q

V

-

V

olume Flow, m /

s

3

q

V

-

V

olume Flow, m /

s

3

q

V

-

V

olume Flow, m /

s

3

p

S

F - F

a

n

S

t

a

tic Pre

ss

ure, P

a

p

S

F - F

a

n

S

t

a

tic Pre

ss

ure, P

a

p

S

F - F

a

n

S

t

a

tic Pre

ss

ure, P

a

0.8

0.6

0.6

4.0

2.0

2.0

6.0

4.0

4.0

10.0

6.0

6.0

20

20

20

60

60

60

40

40

40

100

100

100

200

200

400

= Avg. dB(A) @ 3m

= Avg. dB(A) @ 3m

= Avg. dB(A) @ 3m

4 Pole

24 rev/

s

ec

S

y

s

tem

Line

s

600

0804

0714

74 73

74

72

800

400

200

15.0

10.0 15.0

10.0

64

71

68

66

62

73

62

70

S

y

s

tem

Line

s

0806

1006

0716

6 Pole

16 rev/

s

ec

57

62

61

59

56

64

57

62

S

y

s

tem

Line

s

0808

1008

0718

8 Pole

12 rev/

s

ec

82

80

1004

2.0

1.0

1.0

0634

0564

0504

74

76

74

71

71

70

69

67

66

64

64

65

0636

0566

0506

69

61

61

62

63

58

62

54

57

58

0638

55

54

60

56

1.0

The axial roof ventilators shall be of the Beta Industrial Series

as designed and manufactured by Fantech Pty. Ltd.

The axial impellers shall be adjustable pitch manufactured

with blades of GRP, nylon, aluminium or anti-static

material. (GRP is standard).

The unit base shall be of pressed galvanised steel and shall

incorporate an entry cone to minimise entry losses to the fan.

Windbands shall be of fibreglass or galvanised steel.

The base may be powder-coated if required (optional extra).

All models shall incorporate fans fully tested to

BS848:Part 1, 1980 for air flow and BS848:Part 2, 1985 for noise.

Smoke-Spill Applications

The axial roof ventilators shall be of the RSSL vertical discharge

Beta Industrial Series as designed and manufactured by Fantech

Pty. Ltd.

The windbands shall be constructed from galvanised steel.

Impellers shall be adjustable pitch manufactured from aluminium

and constructed to suit the elevated temperatures, with blades

pinned as required by the manufacturer.

All fans shall be tested to meet the air flow, temperature

and structural requirements of AS/NZS1668.1:1998

and AS/NZS 4429:1999.

Maglok

®

Ref.

J-8

Model

RVLE...

RSSL...

A

†

B

C max D F

0504/6

670

50

182

550

80

0564/6

670

50

182

550

80

0634/6/8

780

100

285

690

80

0714/6/8

780

100

267

690

80

0804/6/8

860

100

338

765

80

1004/6/8

1080 100

338

855

80

Dimensions, mm

ANCILLARY EQUIPMENT

SUGGESTED SPECIFICATION

DIMENSIONS

D-9

Scan the QR

code to view

more information

online.

Variable speed drives

Ref.

M-8/13