© FANTECH
2016
D
ROOF MOUNTED FANS
D-65
Model
Number
Fan
Speed
rev/sc
Avg.
dB(A)
@ 3m
Single-phase
Max
°C
Watts Amps*
PFC316
**
PFC314
PFA306
PFA304
PFA302
15
23
16
22
41
42
48
39
44
55
70
150
50
90
180
0.54
0.66
0.23
0.41
0.79
40
40
50
50
50
48
56
39
49
64
54
58
53
54
67
54
58
47
58
70
60
66
54
63
75
64
69
64
67
74
68
77
64
67
74
76
81
58
66
67
PFC316
PFC314
PFA306
PFA304
PFA302
4k
2k
1k
500
125 250
63
In-duct Sound Power Levels
L
w
dB re 1pW
Model
Number
8.4
PFC316
8.7
PFC314
6.5
E D
PFA306
BØ
6.5
PFA304
C
6.9
A
PFA302
Model
Number
Dimensions, mm
Approx.
weight
kg
Approx.
volume
m
3
290 640 265 100
0.13
570
100
Ø290
The Inlet Spigot, IS30P, is designed for applications where
ducting is required. Care should be taken when installing
ductwork as neither the spigot nor the roof unit base is designed
for weight-bearing.
* Amperages shown are a guide only, refer to our Sales Department for accurate
figures at time of order.
** Not speed controllable
Sound Power Levels shown are for the Inlet Side of the unit.
Dimension F:-
Trimdek
*
620
Klip-Lok 406* 440
Klip-Lok 700* 497
Custom Orb
*
500
Spandek
*
490
Brownbuilt 900
†
508
IS30P - INLET SPIGOT
* Registered trade mark of Bluescope Steel Limited
† Available in New Zealand only
DIMENSIONS
TECHNICAL DATA
NOISE DATA
PROFILE FAN SERIES
0.04
0.02
0.06
0.6 0.4
0.2
0.1
20
40
60
100
200
400
q
V
- Volume Flow, m /s
3
p
S
F - Fan Static Pressure, Pa
Exhaust Air
PFA304
PFA306
PFC316
PFC314
PFA302
System
Lines
44
39
55
42
dB(A) @ 3m: Inlet Side =
48
Scan the QR Code
to view more
information online.