EZIFIT ROOF SERIES - BUSHFIRE CODE COMPLIANT

ROOF MOUNTED FANS

D

© FANTECH

2016

D-54

ECE

Ezifit Thru Roof

Fan diameter in cm

Fan speed, no. of poles

Bushfire Code Compliant

BFC

ANCILLARY EQUIPMENT

B (max)

A

C

D

Model

A

†

B

†

C D EØ

App.

wt.

kg

App.

vol.

m

3

ECE152-BFC

ECE154-BFC

200 250 55 256 286 5

0.025

ECE204-BFC

350 410 55 315 445 10 0.12

Dimensions, mm

HOW TO ORDER

DIMENSIONS

SUGGESTED SPECIFICATION

The roof ventilators shall be of the Ezifit Roof Series with

bushfire code compliance as designed and manufactured by

Fantech Pty Ltd.

The backward-curved centrifugal fans shall be direct-driven by

continuous rated, speed-controllable external rotor motors

with thermal protection.

They shall be constructed from galvanised steel, be of

downflow discharge design and include a 3-pin plug and

lead.

Ember protection mesh shall be bronze or steel with openings

a maximum of 2mm.

All data shall be based on tests on a complete assembled

unit according to ISO5801:2007 for air flow and BS848:Part 2,

1985 for noise.

DESCRIPTION

The Ezifit Roof Series, with bushfire code compliance, has been

developed and tested for exhaust air applications in bushfire

prone regions. They are driven by a high performance

centrifugal fan and have a low profile design. They can exhaust

from a number of points within the building and are available

in 150 and 200mm fan sizes.

Typical Applications

Exhausts from kitchens, laundries, bathrooms, ensuites, toilets

and rangehoods in homes and small commercial premises in

bushfire prone areas.

Features

O

Robust, galvanised steel construction.

O

Speed-controllable with electronic controller.

O

High performance, low noise backward-curved centrifugal

impellers.

O

High quality bronze mesh provides ember protection.

O

Comes with convenient 3-pin plug and lead.

O

Designed for downflow discharge.

O

Can be mounted at angles up to 30°.

O

Powder coated finish is an optional extra.

O

Compliant to AS3959:2009 up to and including BAL-40.

Construction

Cowls are of galvanised steel

Ember protection - bronze mesh with max. 2mm aperture

Backward-curved centrifugal impellers

3-pin plug and lead included

Motors

Type - external rotor, squirrel cage induction motors

Electricity supply - 230V, single-phase, 50/60Hz

Bearings - sealed-for-life, ball

Can be speed controlled

See pages O-2/3 for details on these motors

Internal Thermal Protection

ECE152-BFC & ECE154-BFC - Manual-reset type

ECE204-BFC - Auto-reset type

Testing

Air flow to ISO5801:2007

Based on noise tests to BS848:Part 2, 1985

Special note

Construction of buildings in bushfire prone areas

AS3959:2009, clause 6.6.5(b) "Roof penetrations" states:

Openings in vented roof lights, roof ventilators or vent pipes

shall be fitted with ember guards made from a mesh or

perforated sheet with a maximum aperture of 2mm, made of

corrosion-resistant steel, bronze or aluminium.

VA - Speed controller

Ref.

M-5

Backdraft dampers

Ref.

J-3

Ceiling Grilles

Ref.

L-12/14

CC - Circular attenuator

Ref.

H-16

VZ - Run-on Timer

Ref.