Table of Contents Table of Contents
Previous Page  204 / 416 Next Page
Information
Show Menu
Previous Page 204 / 416 Next Page
Page Background

GE SERIES

ROOF MOUNTED FANS

D

© FANTECH

2016

D-58

C

G

GE

S

eries centrifu

g

al

D

-

3

phase

E -

1

phase

Fan diameter. in cm

Fan speed, number of poles

S

pecial requirements

e

g

.

S

pecial finishes etc.

Amperages for motors can be obtained at time of order.

TECHNICAL DATA

NOISE DATA

HOW TO ORDER

Model

CGD..

CGE..

Nom.

Speed

rev/sec

Low Air

Flow

High Air

Flow

CGE..

1 ph.

CGD..

3 ph.

354

24

53

52

0.55 0.55

356

16

44

44

-

0.37

404

24

57

55

0.55 0.55

406

16

45

45

-

0.37

454

24

60

58

0.55 0.75

456

16

48

47

-

0.37

504

24

63

62

1.5 1.5

506

16

51

51

-

0.75

564

24

66

66

-

3.0

566

16

55

55

-

1.1

634

24

70

71

-

4.0

636

16

61

59

-

1.1

638

12

47

51

-

0.55

716

16

64

62

-

2.2

718

12

49

54

-

1.1

Model

CGD..

CGE..

63 125 250 500 1k 2k 4k 8k

354

Inlet

28 26 22 19 10 12 11 1

356

Inlet

34 26 23 20 15 9 4 1

404

Inlet

28 26 21 18 11 12 12 5

406

Inlet

33 28 22 19 14 10 7 3

454

Inlet

28 26 21 18 12 13 13 9

456

Inlet

31 30 21 18 13 11 9 5

504

Inlet

27 27 22 16 13 13 13 10

506

Inlet

31 30 23 17 13 11 9 7

564

Inlet

26 27 23 14 13 12 12 10

566

Inlet

30 30 24 16 13 11 9 8

634

Inlet

24 28 24 12 13 11 12 10

636

Inlet

29 30 25 15 13 11 9 9

638

Inlet

29 28 24 15 15 10 11 7

716

Inlet

29 30 25 15 13 11 9 9

718

Inlet

29 28 24 15 15 10 11 7

Avg. dB(A) @ 3m

In-Duct Spectrum Corrections, dB*

*Add the In-Duct Spectrum Corrections to the closest dB(A) level shown on the fan

curve to obtain the In-Duct Sound Power Level on the Inlet Side of the unit.

Motor kw

DESCRIPTION

The GE Series of vertical exhaust centrifugal roof units has been

specifically designed to exhaust grease and oil laden air from

applications such as fast food and restaurant kitchens. The

design incorporates a grease/water separator which plumbs

excess water away from the unit while retaining the oil in a

reservoir for later removal.

There are 7 sizes in the range extending from 350 to 710mm

diameter.

Typical Applications

Exhausts grease and oil laden air from fast food shops, cafes

and restaurant kitchens.

Features

O

Robust, galvanised construction.

O

Choice of speeds available.

O

Fitted with a high performance backward-curved

centrifugal fan.

O

Quick release toggle clamps on windband provide easy

access for cleaning and maintenance of impeller.

O

Backward tilting fan body allows easy access for cleaning

unit base.

O

Grease/water separator retains oil in a reservoir for later

removed.

Construction

Galvanised steel construction with a powder-coated finish.

Backward-curved centrifugal impellers.

Motors

Type - standard squirrel cage induction motors

Electricity supply - single or three-phase to suit a wide range of

voltages and frequencies

Bearing - sealed-for-life, ball

Speed-controllable using variable speed drives

See pages O-3/4 for details on these motors

Internal Thermal Protection

Thermistors can be supplied on request

Testing

Air flow to BS848:Part 1, 1980

Noise tests to BS848,Part 2, 1985

Wiring Diagram

See pages N-6/7, diagrams DD 1, 2, 3, 8, 9.