Table of Contents Table of Contents
Previous Page  121 / 416 Next Page
Information
Show Menu
Previous Page 121 / 416 Next Page
Page Background

© FANTECH

2016

C-5

AXIAL FLOW FANS PERFORMANCE DATA

C

AXIAL FLOW FANS GENERAL INFORMATION

Handing

Right and left-hand blades are available enabling the selection of contra-rotating or

multi-stage axial flow fans up to 2000mm diameter. If contra-rotating fans of a

larger diameter are required please refer to our sales department.

Standard Material

GRP blades will be supplied for normal clean ventilation applications as standard

except where otherwise specified, or where local regulations prohibit their use.

Balance

The balance of all impellers is carefully checked before leaving our facilities to

ensure vibration-free running.

Fully-adjustable Blades

All impeller pitch-angles are fully adjustable. For the Elta Range, up to size 1400,

the required blade angles are set on jigs but sizes up to 1000 may also be set

utilising the graduated scale at the root of each blade. For the Elta 2000 Range,

pitch angle setting is by protractor.

OPERATING SPEEDS AND TEMPERATURES

Impellers installed for O.E.M. applications are submitted to the vibration, cyclic

torques and temperature cycles that prevail within the item of equipment. It can

therefore be misleading to state maximum conditions unless the full operating

environment is known, as all the above points can be inter-related.

The table below should be used as a guide only. For accurate figures use the

Fantech Product Selection Program.

REVERSAL OF AIR FLOW

Air flow direction can be reversed on fans fitted with three-phase motors

by simply reversing the direction of rotation.

The impact on performance in reverse rotation approximates to:-

Air flow reduction

-30%

Pressure reduction

-55%

Power reduction

-25%

TRULY REVERSIBLE

Equal volume flow in both directions can be achieved by blade reversal

procedures carried out when the impeller is being assembled.

The impact on performance when compared to standard performance

approximates to:-

Air flow reduction

-15%

Pressure reduction

-25%

Power reduction

-20%

Blade Material

Temperature Range Limiting Tip Speed**

Elta 1000 Impeller*

Aluminium

-40°C to +200°C

115m/s

GRP

-40°C to +70°C

95m/s

Nylon

-40°C to +100°C

115m/s

Anti-static GRP

-40°C to +70°C

95m/s

Elta 1400 & 2000 Impellers

#

Aluminium

-40°C to +200°C

105m/s

GRP

-40°C to +70°C

95m/s

Anti-static GRP***

-40°C to +70°C

95m/s

* Up to 1000mm diameter ** Applicable to 20°C *** 1400 Series only

#