N-7
© FANTECH
2016
INSTALLATION, WIRING DIAGRAMS & FAN TROUBLE SHOOTING
WIRING DIAGRAMS - STANDARD MOTORS
N
3Ø WIRING DIAGRAMS
1Ø WIRING DIAGRAMS
(Form A)
M
3~
M
3~
High speed delta ( ) connection
Low speed star ( ) connection
W2 or White
W2 or White
U2 or Black
U2 or Black
V2 or Orange
V2 or Orange
U1 or Red
U1 or Red
V1 or Yellow
V1 or Yellow
W1 or Blue
W1 or Blue
Thermal
Contacts (TB)
White
Thermal
Contacts (TB)
White
L1
L1
L2
L2
L3
L3
E
E
Codes: ..40. to 63.
Codes: ..40. and upwards
Diagram DD5
TWO-SPEED MOTORS
For all other SINGLE-PHASE wiring
diagrams refer to the manufacturers
data on the motor.
Diagram DD6
Diagram DD8
M
1 ~
L N E
Diagram DD9
M
1 ~
L N E
White
Brown
Blue
L1
L2
N
S/C
Bridge L1 and L2 if speed
controller (S/C) is not required
Diagram DD7
L N E
L1
L2
N
S/C
Z2
U2
Z1
U1
Cap.
Thermal
contacts (TB)
white
M
1 ~
Z2 - Yellow (AUX)
Z1 - Blue
U2 - Black (MAIN)
U1 - Red
Clockwise
Anti-Clockwise
L N E
L1
L2
N
S/C
Z1
U2
Z2
U1
Cap.
Thermal
contacts (TB)
white
M
1 ~
Z1 - Blue
Z2 - Yellow
(AUX)
U2 - Black (MAIN)
U1 - Red
Bridge L1 and L2 if speed
controller (S/C) is not required
}
(COM)
Note:
This diagram suits
VA2.0
and VA2.8 only. When using the AVA5.0,
VA5.0 and VA8.0 speed controllers,
use the AUX, MAIN and COM connections.
speed controllers,
Bridge L1 and L2 if speed
controller (S/C) is not required
}
(COM)
Note:
This diagram suits
VA2.0
and VA2.8 only. When using the AVA5.0,
VA5.0 and VA8.0 speed controllers,
use the AUX, MAIN and COM connections.
speed controllers,
1Ø WIRING DIAGRAMS
(Form B)
* Airflow direction base on left-hand blade installation.
* Airflow direction base on left-hand blade installation.
Airflow
Airflow
Airflow
Airflow
*
*
These diagrams are current at the time of publication, check the wiring diagram supplied with the motor.